The wall sleeve be installed a minimum of 36 from the ceiling.
Ptac wall sleeve installation instructions.
All wall and window wall installations must provide for proper drainage.
For sunrooms and modular buildings adhere to their installation instructions for supporting and sealing sleeve to their frames.
Wall case should be sealed caulked to the inside wall on all four 4 sides.
Prepare and install the new wall sleeve according to the instructions below.
To ensure proper airflow and filter removal it is recom mended installation of the wall sleeve be a minimum of 36 from the ceiling.
Consult a licensed contractor as needed.
The wall sleeve must be fastened securely before installing the air conditioner unit.
For new installs ensure the wall is properly framed to support the weight and dimensions of the wall sleeve and air conditioner.
Figure 4 minimum interior and exterior note.
Inches mm inches mm inches mm wall sleeve only 3 75 0 0 0 0 subbase kit 3 75 3 1 4 85 2 3 4 70.
See the drain kit for internal actual installation instructions.
Page 3 pre installation considerations before proceeding with the sleeve installation ensure the following guidelines for locating the wall opening and sleeve are met.
All wall and window wall installations must provide for proper drainage.
While the dimensions may appear to be incompatible the 2 devices should fit properly.
When you visit any website it may store or retrieve information on your browser mostly in the form of cookies.
In applications where the drain holes on the ptac wall sleeve are not exposed beyond the wall an internal drain system is recommended.
This information might be about you your preferences or your device and is mostly used to make the site work as you expect it to.
When a drain kit is to be installed do so before top of wall sleeve installing the wall sleeve in the wall.
Failure to install and maintain our product according to these instructions may void any product warranty.
Wall sleeve installation 920 087 04 8 05 wall sleeve installation instructions pdxws note.
For sunrooms and modular buildings adhere to their installation instructions for supporting and sealing sleeve to their frames.
Wall case must be sealed caulked to outside wall on all four 4 sides.
Installation guidelines for sealing ptac sleeves read these instructions completely before starting any installation.
There is a portion of the air conditioner which extends a few inches back into the room.
Standard steel wall cases are 42 w 16 h 13 3 4 d.
16 24 28 and 31 deep cases are available for thicker walls.
Insure that the unit is only installed in a wall structurally adequate to support the unit including the sleeve chassis and accessories.
If the sleeve projects more than 8 into the room a sub base or other means of support must be used.
The sleeve will fit flush in the wall extending outside the structure.